Project

General

Profile

XDirection flipped when using Visicut with Laos board in K40 ยป config.txt

Techrat, 2013-05-03 04:11

 
;
; Config file for HPC laser LS-3020
;
; for the version with flatcable and 26x32 honeycomb
; as distributed in may 2012
;
; configuration made by Jaap Vermaas <jaap@tuxic.nl>
;
; Save on MBED in the root, as "config.txt"
;
net.ip 10.0.0.150 ; IP address [xxx.xxx.xxx.xxx]
net.netmask 255.255.0.0 ; netmask [xxx.xxx.xxx.xxx]
net.gateway 10.0.0.1 ; gateway
net.dns 10.0.0.1 ; DNS server
net.dhcp 0 ; Enable DHCP for IP address [0/1]
net.port 69 ; Communication socket port number []

sys.debug 1 ; debug flags bit0=verbose,
; bit1=log to serial, bit2=log to file
sys.autohome 1 ; Enable automatic homing at startup [1/0]
;(or wait for cover to close)
sys.nodisplay 1 ; Disable the display [1/0]
sys.i2cbaud 0 ; I2C display baudrate [Hz]

laser.enable 0 ; Laser enable signal polarity [0/1]
laser.on 1 ; Laser on signal polarity [0/1]
laser.pwm.min 70 ; minimum pwm value [%]
laser.pwm.max 100 ; maximum pwm value [%]
laser.pwm.freq 1000 ; pwm frequency [Hz]

motion.enable 0 ; Enable signal state to enable motors [0/1]
motion.homespeed 50 ; Homing speed [mm/sec]
motion.speed 100 ; max linear speed [mm/sec]was 50
motion.accel 500 ; linear acceleration [mm/sec2]
motion.tolerance 100 ; tolerance [1/1000 units]

; old firmware: set speed in [usec]
motion.highspeed 100 ; speed in [usec]

; Next values are valid for axis x,y,z and e
x.pol 1 ; home/limit sensor polarity [1/0]
x.scale 158516 ; axis scaling [steps/meter]
;x.scale 79258
; use negative number to invert direction [1/0]
x.homedir 1 ; state of the direction signal when homing
x.home 320000 ; home positions [um] was 400000
x.min 0 ; minimal position [um]
x.max 320000 ; maximum position [um]
x.rest 300000 ; rest position [um] was 3000000
x.speed 1000 ; maximum speed [mm/sec]
x.invert 0 ; Invert signal polarity for step signal [1/0]

; Now for the Y-axis:
y.pol 1 ; home/limit sensor polarity [1/0]
y.scale 158516 ; axis scaling [steps/meter]
;y.scale 79258
; use negative number to invert direction [1/0]
y.homedir 1 ; state of the direction signal when homing
y.home 180000 ; home positions [um]
y.min 0 ; minimal position [um]
y.max 180000 ; maximum position [um]
y.rest 180000 ; rest position [um]
y.speed 1000 ; maximum speed [mm/sec]
y.invert 0 ; Invert signal polarity for step signal [1/0]

; Z-axis not in use for HPC
; z.min 0
; z.max 200000
; z.home 100000
    (1-1/1)