LAOS configuration file » History » Revision 7
Revision 6 (jaap, 2012-11-09 08:14) → Revision 7/31 (parag0n, 2013-01-09 18:29)
h1. LAOS configuration file The LAOS Mainboard looks for a "config.txt" file on the MBED, to obtain some essential settings on power-up. It can be set up and modified my plugging the MBED into USB, which will cause it to appear as a USB drive with that config.txt file on it. The proper settings will depend on your configuration, attached is a file which works with the [[HPC LS3020]], [[LAOS mainboard v0.3]], and the July 7th release of the [[LAOS firmware]]. h3. Location The configuration file is located on the MBED USB partition and is named *config.txt*. When a *config.txt* file is found on your SD card, this will take precedence over the file on the MBED. h3. Sample configurations Sample configuration files can be found at the end of this page. Copy it and edit it to match your needs. If you configure LAOS for a new machine, please add your configuration file to this page. h3. Updating the configuration file You can update the file by connecting the MBED to a PC with the USB connector. It should be visible as a small (2Mbyte) USB disk (label: MBED). Copy the configuration file to the root of this disk and eject the disk, using the appropriate method for your operating system (unmount, eject, save remove, etc.). You need to reset the laser to read the new configuration file. Use the reset button on the MBED or power down the system (make sure you remove the USB cable, or the MBED will not power down). h3. Format The general format is: <pre> name value </pre> Each value is a single word, without spaces. h4. Comments Comments can be included with a semicolon (";") character. All characters after the semicolon (up to a newline) are ignored. Multiple Whitespace and newlines are ignored. h4. Sections The file contains various sections that configure different parts of the system. The exact location of these sections (and ordering of their parameters) is not significant. Each parameter has a default value that is used if the parameter is not found in the configuration file, so they can be omitted if the defaults suit you. It is advised to include all parameters in the file, because the defaults may change in the future, causing your system to fail when you update the firmware. h4. Network The network parameters define the network configuration. The minimal network configuration is '''net.dhcp 1'''. In this case, the laser will request a IP address from a DHCP server in the network, and is accessible via port 2000. You may need to instruct your DHCP server to hand out a fixed IP address, or assign a DNS entry to the laser, otherwise it may be difficult to 'find' the laser in the network. <pre> net.dhcp 0 ; Enable DHCP for IP address [0/1], if enabled, the other network settings (except port number) are not used net.port 2000 ; Communication socket port number [] net.ip 192.168.0.111 ; IP address [xxx.xxx.xxx.xxx] net.netmask 255.255.255.0 ; netmask [xxx.xxx.xxx.xxx] net.gateway 192.168.0.1 ; gateway net.dns 192.168.0.1 ; DNS server net.port 69 ; Port the TFTP server is available on </pre> h4. System This section defines the behavior of the system. <pre> sys.autohome 0 ; Enable automatic homing at startup [1/0] or wait for cover to close (you need a cover sensor) sys.autozhome 0 ; Enable automatic homing of Z axis at startup [1/0] or wait for cover to close (you need a cover sensor) sys.nodisplay 0 ; Disable the I2C display [1/0] sys.i2cbaud 100000 ; I2C display baudrate [Hz] sys.cleandir 1 ; Clean out directory on startup </pre> h4. Laser The properties of the laser are described here. To invert the laser polarity, switch round the values in laser.pwm.min and laser.pwm.max here <pre> laser.enable 0 ; Laser enable signal polarity [0/1] laser.on 1 ; Laser on signal polarity [0/1] laser.pwm.min 0 ; minimum pwm value [%] laser.pwm.max 100 ; maximum pwm value [%] laser.pwm.freq 20000 ; pwm frequency [Hz] </pre> h4. Motion The motion section defines the overall motion properties. <pre> motion.enable 0 ; Enable signal state to enable motors [0/1] motion.homespeed 100 ; Homing speed [microsecond/step] motion.speed 400 ; max linear speed [millimeter/sec] motion.accel 1000 ; linear acceleration [millimeter/sec2] motion.tolerance 50 ; tolerance for cornering [micrometer] (larger is faster, but less accurate corners) </pre> h4. Axis The various axis are configured with their respective values. An axis definition may exist for up to four axis (x,y,z,e). At least two should be configured (x and y). <pre> ; Next values are valid for axis x,y,z and e x.pol 0 ; home/limit sensor polarity [1/0]. Inverts the input of the switch, so it can be a N.O. or N.C. switch. x.homedir 0 ; state of the direction signal when homing (axis should move towards home-sensor) [1/0] x.home 320000 ; home positions [micrometer], this is the position we assume the home switch to be located x.scale -136986 ; axis scaling [steps/meter], use negative number to invert direction signal x.invert 1 ; Invert signal polarity for step signal [1/0] x.min 0 ; minimal position [micrometer]. The axis is not allowed to move beyond this position x.max 320000 ; maximum position [micrometer]. The axis is not allowed to move beyond this position x.rest 310000 ; rest position [micrometer]. The position the axis assumes before/after a job x.speed 1000 ; maximum speed [millimeter/sec]. The maximum speed this axis is allowed to move at </pre>