1
;
2
; Config file for HPC laser LS-3020
3
; 
4
; for the version with flatcable and 26x32 honeycomb
5
; as distributed in may 2012
6
;
7
; configuration made by Jaap Vermaas <jaap@tuxic.nl>
8
;
9
; Save on MBED in the root, as "config.txt"
10
;
11
net.ip 192.168.1.111		; IP address [xxx.xxx.xxx.xxx] 
12
net.netmask 255.255.255.0	; netmask [xxx.xxx.xxx.xxx] 
13
net.gateway 192.168.1.1	; gateway
14
net.dns 192.168.1.1		; DNS server
15
net.dhcp 0			; Enable DHCP for IP address [0/1]
16
net.port 69			; Communication socket port number []
17

    
18
sys.debug  1			; debug flags bit0=verbose, 
19
				; bit1=log to serial, bit2=log to file
20
sys.autohome 1			; Enable automatic homing at startup [1/0] 
21
				;(or wait for cover to close)
22
sys.nodisplay 0			; Disable the display [1/0]
23
sys.i2cbaud 0			; I2C display baudrate [Hz]
24

    
25
laser.enable 0			; Laser enable signal polarity [0/1]
26
laser.on 0				; Laser on signal polarity [0/1]
27
laser.pwm.min  0		; minimum pwm value [%]
28
laser.pwm.max  90		; maximum pwm value [%]
29
laser.pwm.freq 1000		; pwm frequency [Hz]
30
;laser.pwm.freq 20000	; pwm frequency [Hz]
31

    
32

    
33
motion.enable  0		; Enable signal state to enable motors [0/1] 
34
motion.homespeed  50		; Homing speed [mm/sec]
35
motion.speed  50		; max linear speed [mm/sec]
36
motion.accel  500		; linear acceleration [mm/sec2]
37
motion.tolerance  100		; tolerance [1/1000 units]
38

    
39
; old firmware: set speed in [usec]
40
motion.highspeed 100	; speed in [usec]
41

    
42
; Next values are valid for axis x,y,z and e
43
x.pol 0				; home/limit sensor polarity [1/0]
44
;x.scale 158516			; axis scaling [steps/meter]
45
;x.scale -79258  
46
x.scale -158516			; axis scaling [steps/meter]
47
					; use negative number to invert direction [1/0]
48
x.homedir 0			; state of the direction signal when homing
49
x.home 350000			; home positions [um] 
50
x.min 0				; minimal position [um]
51
x.max 350000			; maximum position [um]
52
x.rest 350000			; rest position [um]
53
x.speed 1000			; maximum speed [mm/sec]
54
x.invert 0			; Invert signal polarity for step signal [1/0]
55

    
56
; Now for the Y-axis:
57
y.pol 0				; home/limit sensor polarity [1/0]
58
y.scale 158516   		; axis scaling [steps/meter]
59
;y.scale 79258
60
				; use negative number to invert direction [1/0]
61
y.homedir 1			; state of the direction signal when homing
62
y.home 200000			; home positions [um]
63
y.min 200000				; minimal position [um]
64
y.max 0			; maximum position [um]
65
y.rest 200000			; rest position [um] 
66
y.speed 1000			; maximum speed [mm/sec]
67
y.invert 0			; Invert signal polarity for step signal [1/0]
68

    
69
; Z-axis not in use for HPC
70
; z.min 0
71
; z.max 200000
72
; z.home 100000