; Config file for HPC laser LS-3020
|
|
;
|
|
; for the version with flatcable and 26x32 honeycomb
|
|
; as distributed in may 2012
|
|
;
|
|
; configuration made by Peter Uithoven (Fablab Amersfoort)
|
|
;
|
|
; Save on MBED in the root, as "config.txt"
|
|
;
|
|
net.ip 10.0.0.16 ; IP address [xxx.xxx.xxx.xxx]
|
|
net.netmask 255.255.255.0 ; netmask [xxx.xxx.xxx.xxx]
|
|
net.gateway 10.0.0.1 ; gateway
|
|
net.dns 10.0.0.1 ; DNS server
|
|
net.dhcp 1 ; Enable DHCP for IP address [0/1]
|
|
net.port 69 ; Communication socket port number []
|
|
|
|
sys.debug 1 ; debug flags bit0=verbose,
|
|
; bit1=log to serial, bit2=log to file
|
|
sys.autohome 1 ; Enable automatic homing at startup [1/0]
|
|
;(or wait for cover to close)
|
|
sys.nodisplay 0 ; Disable the display [1/0]
|
|
sys.i2cbaud 0 ; I2C display baudrate [Hz]
|
|
|
|
laser.enable 0 ; Laser enable signal polarity [0/1]
|
|
laser.on 0 ; Laser on signal polarity [0/1]
|
|
laser.pwm.min 47 ; minimum pwm value [%]
|
|
laser.pwm.max 165 ; maximum pwm value [%]
|
|
laser.pwm.freq 1000 ; pwm frequency [Hz]
|
|
;laser.pwm.freq 20000 ; pwm frequency [Hz]
|
|
|
|
|
|
motion.enable 0 ; Enable signal state to enable motors [0/1]
|
|
motion.homespeed 100 ; Homing speed [mm/sec]
|
|
motion.speed 50 ; max linear speed [mm/sec]
|
|
motion.accel 500 ; linear acceleration [mm/sec2]
|
|
motion.tolerance 100 ; tolerance [1/1000 units]
|
|
|
|
; old firmware: set speed in [usec]
|
|
motion.highspeed 100 ; speed in [usec]
|
|
|
|
; Next values are valid for axis x,y,z and e
|
|
x.pol 0 ; home/limit sensor polarity [1/0]
|
|
x.scale -45000; ; axis scaling [steps/meter]
|
|
; use negative number to invert direction [1/0]
|
|
x.homedir 1 ; state of the direction signal when homing
|
|
x.home 0; 350000 ; home positions [um]
|
|
x.rest 0; 350000 ; rest position [um]
|
|
x.invert 1 ; Invert signal polarity for step signal [1/0]
|
|
x.min 0 ; minimal position [um] NOT USED
|
|
x.max 350000 ; maximum position [um] NOT USED
|
|
x.speed 1000 ; maximum speed [mm/sec] NOT USED
|
|
|
|
; Now for the Y-axis:
|
|
y.pol 0 ; home/limit sensor polarity [1/0]
|
|
y.scale -45000; ; axis scaling [steps/meter]
|
|
; use negative number to invert direction [1/0]
|
|
y.homedir 0 ; state of the direction signal when homing
|
|
y.home 210000 ; home positions [um]
|
|
y.rest 210000 ; rest position [um]
|
|
y.invert 1 ; Invert signal polarity for step signal [1/0]
|
|
y.min 200000 ; minimal position [um] NOT USED
|
|
y.max 0 ; maximum position [um] NOT USED
|
|
y.speed 1000 ; maximum speed [mm/sec] NOT USED
|
|
|
|
; Z-axis not in use for HPC
|
|
; z.min 0
|
|
; z.max 200000
|
|
; z.home 100000
|