Project

General

Profile

Actions

Bug #50

closed

Change CAN bus connector to RJ11/RJ12

Added by Anonymous over 11 years ago. Updated over 11 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
Mainboard
Target version:
Start date:
2012-09-30
Due date:
% Done:

100%

Estimated time:

Description

The Tosca project has selected RJ11 as CAN bus connector. It might be an idea to adopt it here as well. That's a 6-pin jack with the centre 4 wires as follows:

  • +5V
  • CAN-H
  • CAN-L
  • GND

From what I can tell, pinout is the same as now - could also be added extra (same space), so that 4-pin 0.1" header can still be used instead.


Files

rj12-detail.png (36.4 KB) rj12-detail.png Anonymous, 2012-10-01 00:58
board.png (29.5 KB) board.png Anonymous, 2012-10-01 13:07
canrj10.jpg (7.8 KB) canrj10.jpg Anonymous, 2012-10-01 13:07
chip.png (12.9 KB) chip.png Anonymous, 2012-10-01 13:07